Search results for "Mr images"

showing 10 items of 14 documents

Adaptive Bias Field Correction: Application on Abdominal MR Images

2017

Segmentation of medical images is one of the most important phases for disease diagnosis. Accuracy, robustness and stability of the results obtained by image segmentation is a major concern. Many segmentation methods rely on absolute values of intensity level, which are affected by a bias term due to in-homogeneous field in magnetic resonance images. The main objective of this paper is two folded: (1) To show efficiency of an energy minimization based approach, which uses intrinsic component optimization, on abdominal magnetic resonance images. (2) To propose an adaptive method to stop the optimization automatically. The proposed method can control the value of the energy functional and sto…

Adaptive biasmedicine.diagnostic_testbusiness.industryComputer scienceMagnetic resonance imagingPattern recognitionImage segmentationEnergy minimizationRobustness (computer science)medicineSegmentationArtificial intelligenceMr imagesbusinessEnergy functional
researchProduct

Magnetic resonance chondro-crassometry (MR CCM): a method for accurate determination of articular cartilage thickness?

1996

A method for the assessment of articular cartilage thickness based on MRI is presented and its accuracy and reproducibility tested. Six specimens of human patellae were imaged, using a fat-suppressed FLASH 3D sequence, and sectioned with a high-precision band saw. The regional distribution of articular cartilage thickness was determined from the MR images and from the anatomical sections (intervals of 0.5 mm). With image analysis 50-90% of the image points were found to lie within exactly the same thickness interval in corresponding patterns, and less than 17% deviated more than 0.5 mm. More than 85% of all pixels were reproducible with MRI after new positioning of the joint. No influence o…

AdultCartilage ArticularMaleMaterials scienceArticular cartilageNuclear magnetic resonanceReference ValuesmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedAged 80 and overReproducibilityMeasurement methodmedicine.diagnostic_testAnthropometryCartilageReproducibility of ResultsMagnetic resonance imagingCartilage thicknessMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structureReference valuesFemaleMr imagesSoftwareMagnetic resonance in medicine
researchProduct

Value of texture analysis on gadoxetic acid–enhanced MRI for differentiating hepatocellular adenoma from focal nodular hyperplasia

2019

OBJECTIVE. The objective of our study was to assess the diagnostic performance of texture analysis (TA) on gadoxetic acid-enhanced MR images for differentiation of hepatocellular adenoma (HCA) from focal nodular hyperplasia (FNH).MATERIALS AND METHODS. This study included 40 patients (39 women and one man) with 51 HCAs and 28 patients (27 women and one man) with 32 FNH lesions. All lesions were histologically proven with preoperative MRI performed with gadoxetic acid. Two readers reviewed all the imaging sequences to assess the qualitative MRI characteristics. The T2-weighted fast spin-echo, hepatic arterial phase (HAP), and hepatobiliary phase (HBP) sequences were used for TA. Textural fea…

AdultGadolinium DTPAMaleGadoxetic acidCarcinoma Hepatocellulargenetic structuresAdolescenthepatocellular adenomaContrast MediaSensitivity and Specificity030218 nuclear medicine & medical imagingAdenoma Liver CellDiagnosis Differential03 medical and health sciences0302 clinical medicineImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingTexture (crystalline)Agedfocal nodular hyperplasiabusiness.industryLiver NeoplasmsFocal nodular hyperplasiatexture analysiGeneral MedicineHepatocellular adenomaMiddle Agedmedicine.diseaseImage EnhancementMagnetic Resonance Imagingdigestive system diseases030220 oncology & carcinogenesisFemaleMr imagesNuclear medicinebusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaValue (mathematics)medicine.drugMRI
researchProduct

Fuzzy C-Means Segmentation on Brain MR Slices Corrupted by RF-Inhomogeneity

2007

Brain MR Images corrupted by RF-Inhomogeneity exhibit brightness variations in such a way that a standard Fuzzy C-Means (fcm) segmentation algorithm fails. As a consequence, modified versions of the algorithm can be found in literature, which take into account the artifact. In this work we show that the application of a suitable pre-processing algorithm, already presented by the authors, followed by a standard fcm segmentation achieves good results also. The experimental results ones are compared with those obtained using SPM5, which can be considered the state of the art algorithm oriented to brain segmentation and bias removal.

Artifact (error)BrightnessComputer sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONScale-space segmentationPattern recognitionFuzzy logicBrain segmentationSegmentationComputer visionArtificial intelligenceMr imagesbusinessrf-inhomogeneity bias artifact mri fuzzy c-means segmentationHistogram equalization
researchProduct

Automatic skull stripping in MRI based on morphological filters and fuzzy c-means segmentation

2012

In this paper a new automatic skull stripping method for T1-weighted MR image of human brain is presented. Skull stripping is a process that allows to separate the brain from the rest of tissues. The proposed method is based on a 2D brain extraction making use of fuzzy c-means segmentation and morphological operators applied on transversal slices. The approach is extended to the 3D case, taking into account the result obtained from the preceding slice to solve the organ splitting problem. The proposed approach is compared with BET (Brain Extraction Tool) implemented in MRIcro software.

Computer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSensitivity and SpecificityFuzzy logicPattern Recognition AutomatedFuzzy LogicImage Interpretation Computer-AssistedmedicineHumansSegmentationComputer visionSettore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionimedicine.diagnostic_testSkull Stripping Fuzzy C-means Morphological Filters.business.industrySkullProcess (computing)BrainReproducibility of ResultsMagnetic resonance imagingImage segmentationImage EnhancementMagnetic Resonance ImagingSubtraction TechniquePattern recognition (psychology)Skull strippingArtificial intelligenceMr imagesbusinessAlgorithms2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
researchProduct

Bias artifact suppression on MR volumes.

2007

RF-Inhomogeneity correction is a relevant research topic in the field of Magnetic Resonance Imaging (MRI). A volume corrupted by this artifact exhibits nonuni- form illumination both inside a single slice and between adjacent ones. In this work a bias correction technique is presented, which suppresses this artifact on MR vol- umes scanned from different body parts without any a-priori hypothesis on the artifact model. Theoretical foundations of the method are reported together with experimental results and a comparison is presented with both the 2D version of the algorithm and other techniques that are widely used in MRI literature.

Computer scienceHealth InformaticsSensitivity and SpecificityImaging Three-DimensionalBiasImage Interpretation Computer-AssistedmedicineComputer visionRF-Inhomogeneity Bias Artifact Illumination correction MR Image Homomorphic filterSettore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniArtifact (error)medicine.diagnostic_testbusiness.industryReproducibility of ResultsMagnetic resonance imagingImage EnhancementMagnetic Resonance ImagingComputer Science ApplicationsArtifact suppressionArtificial intelligenceMr imagesbusinessArtifactsSoftwareAlgorithmsVolume (compression)Computer methods and programs in biomedicine
researchProduct

Functional statistics based method for the evaluation of the registration of sequences of 3D perfusion MR images

2011

Accurate registration of medical images is a necessary task for several important diagnosis techniques. Nevertheless, it is a difficult challenge due to movement of the patient, deformations, noise in the signal, etc. Besides, evaluation of the quality of the performed registration is also troublesome, specially when no golden pattern (true result) is available and/or when the signal values may have changed between successive images/volumes to be registered.

Computer sciencebusiness.industryImage registrationStatistical analysisComputer visionNoise (video)Artificial intelligenceMr imagesbusinessSignal2011 IEEE Nuclear Science Symposium Conference Record
researchProduct

A Specialized Architecture for Color Image Edge Detection Based on Clifford Algebra

2013

Edge detection of color images is usually performed by applying the traditional techniques for gray-scale images to the three color channels separately. However, human visual perception does not differentiate colors and processes the image as a whole. Recently, new methods have been proposed that treat RGB color triples as vectors and color images as vector fields. In these approaches, edge detection is obtained extending the classical pattern matching and convolution techniques to vector fields. This paper proposes a hardware implementation of an edge detection method for color images that exploits the definition of geometric product of vectors given in the Clifford algebra framework to ex…

Hardware architectureMultispectral MR images.Settore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniColor histogramComputer scienceColor imagebusiness.industryColor image edge detectionComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONFPGA prototypingApplication-specific processorColor quantizationEdge detectionConvolutionComputer Science::Hardware ArchitectureComputer Science::Computer Vision and Pattern RecognitionRGB color modelComputer visionArtificial intelligenceClifford algebrabusinessImage gradient
researchProduct

Application unit for the administration of contrast gases for pulmonary magnetic resonance imaging: optimization of ventilation distribution for3He-M…

2014

Purpose MRI of lung airspaces using gases with MR-active nuclei (3He, 129Xe, and 19F) is an important area of research in pulmonary imaging. The volume-controlled administration of gas mixtures is important for obtaining quantitative information from MR images. State-of-the-art gas administration using plastic bags (PBs) does not allow for a precise determination of both the volume and timing of a 3He bolus. Methods A novel application unit (AU) was built according to the requirements of the German medical devices law. Integrated spirometers enable the monitoring of the inhaled gas flow. The device is particularly suited for hyperpolarized (HP) gases (e.g., storage and administration with m…

ReproducibilityMaterials sciencemedicine.diagnostic_testMagnetic resonance imaginglaw.inventionPulmonary imagingVolume (thermodynamics)lawAnesthesiaHealthy volunteersVentilation (architecture)medicineRadiology Nuclear Medicine and imagingHyperpolarization (physics)Mr imagesBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

Exponential Entropy Driven HUM on Knee MR Images

2007

A very important artifact corrupting Magnetic Resonance Images is the RF inhomogeneity. This kind of artifact generates variations of illumination which trouble both direct examination by the doctor and segmentation algorithms. Even if homomorphic filtering approaches have been presented in literature, none of them has developed a measure to determine the cut-off frequency. In this work we present a measure based on information theory with a large experimental setup aimed to demonstrate the validity of our approach.

Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionibusiness.industryEntropy Knee Magnetic resonance rf-inhomogeneityImage segmentationInformation theoryExponential functionHomomorphic filteringHumEntropy (information theory)SegmentationComputer visionArtificial intelligenceMr imagesbusinessMathematics2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
researchProduct